COMSPHERE 3800Plus Modems

 

Table 4-3

 

(2 of 3)

 

Top Level Menu Status

 

 

Normal Call

Indicates

Setup Messages

 

 

 

Off Hook

The modem is off-hook and waiting to dial a telephone number.

 

 

Dialing

The remote modem is being dialed.

 

 

Training

The modem is training or retraining.

 

 

EC Negotiating

The local and remote modems are negotiating the highest possible level of error control

 

compatible between both modems. Once a level is selected, this LCD message disappears.

 

 

Call Failure

Indicates

Messages

 

 

 

Busy Signal

The answering modem is busy.

Dial Line in Use

The modem is already operating on dial networks when another call attempt has been issued.

Invalid Number

The modem has dialed a telephone number not stored in a directory location.

No Answer Tone

The answering modem has not answered within the time limit specified by the No Answer

 

Timeout configuration option.

 

 

No Dial ± DTR

The modem cannot dial because DTR is Off.

 

 

No Dial ± Test

The modem cannot dial because it is running a Test.

 

 

No Dial Tone

The modem has aborted the call because it cannot detect a dial tone.

 

 

No Quiet Answer

The modem has detected No Quiet Answer (@) before the time-out setting of the No Answer

 

Disconnect configuration option.

 

 

Trunk Busy

The modem is receiving a fast (trunk) busy.

 

 

Call Disconnect

Indicates

Messages

 

 

 

ATH Disconnect

The modem has disconnected due to an ATH command.

 

 

Bad Lines Disc

The modem has disconnected because the lines do not support the modulation and/or data rate

 

selected.

 

 

No Carrier Disc

The modem disconnects due to the loss of carrier signal from the remote modem.

 

 

DTR Disconnect

The modem has disconnected due to the loss of DTR from the DTE.

 

 

EC Disconnect

The modem has disconnected due to failure to negotiate Error Control mode.

 

 

LongSpace Disc

The modem has disconnected due to the detection of a long space.

 

 

NoData Disc

The modem has disconnected due to a lack of transmitted and received data.

 

 

Disconnecting

The modem has begun the disconnect sequence.

 

 

Rmt Cmnded Disc

The modem has disconnected due to a V.32 or V.34 Cleardown received from the remote

 

modem.

 

 

4-8

November 1996

3980-A2-GB30-20

Page 32
Image 32
Paradyne 3800PLUS manual Normal Call Indicates, Call Failure Indicates, Call Disconnect Indicates Messages

3800PLUS specifications

The Paradyne 3800PLUS is a sophisticated networking device designed for various applications in high-demand environments, such as telecommunications and enterprise networks. This versatile solution is well-regarded for its robust performance, providing reliable and efficient connectivity for businesses and service providers.

One of the standout features of the Paradyne 3800PLUS is its ability to deliver high-speed data transmission. Supporting multiple protocols, it ensures seamless connectivity for data, voice, and video over the same infrastructure, reducing the need for multiple devices and simplifying network management. The device is capable of supporting both synchronous and asynchronous data formats, making it suitable for diverse networking needs.

With its advanced multiple service options, the Paradyne 3800PLUS supports various connection types, including T1, E1, and DSL, allowing it to adapt to different local area network (LAN) settings. This flexibility makes it a preferred choice for organizations that require support for both legacy systems and modern technologies. Furthermore, the device offers built-in support for various network management protocols, such as SNMP, simplifying monitoring and configuration.

Security is a significant concern in today's networking landscape, and the Paradyne 3800PLUS addresses this with integrated security features that help ensure data integrity and privacy. The device supports encryption and authentication techniques, which protect against unauthorized access and safeguard sensitive information transmitted over the network.

The Paradyne 3800PLUS is also designed with ease of use in mind. Its web-based interface simplifies configuration and management, making it accessible for network administrators regardless of their technical expertise. Additionally, the device is equipped with diagnostic tools and indicators that facilitate troubleshooting, enabling quicker resolution of connectivity issues.

In terms of scalability, the Paradyne 3800PLUS can accommodate the growing needs of businesses and service providers. Its modular design allows for easy upgrades and the addition of new features, ensuring that the network infrastructure can evolve with changing demands.

In summary, the Paradyne 3800PLUS stands out as an advanced networking solution known for its high-speed capabilities, support for various protocols, integrated security measures, user-friendly management interface, and scalability. These characteristics make it an ideal choice for organizations seeking a reliable and efficient networking solution to enhance their operations and support future growth.