D

B – Command Line Interface Set Config Command

zoning

Initiates an editing session in which to change switch zoning attributes. The system displays each parameter one line at a time and prompts you for a value. For each parameter, enter a new value or press the Enter key to accept the current value shown in brackets.

Table B-16. Set Config Zoning Parameters

Parameter

Description

 

 

FC-SW-2 AutoSave

Available only when the FC-SW-2

 

Compliant parameter is True, this

 

parameter enables (True) or disables

 

(False) the saving of changes to active

 

zone set in the switch’s permanent

 

memory. Refer to ”FC-SW-2 Compliant”

 

on page B-47. The default is True.

Default Visibility

Enables (All) or disables (None)

 

communication among the switch’s

 

ports/devices and the fabric in the

 

absence of an active zone set. The

 

default is All.

 

 

Examples The following is an example of the Set Config Blade command:

SANbox2-64 108 (admin-config) #> set config blade 1

A list of attributes with formatting and current values will follow.

Enter a new value or simply press the

ENTER key to accept the default value.

If you wish to terminate this process

before reaching the end of the list

press 'q' or 'qq' and the ENTER key to do so.

Configuring Blade in Slot Number: 1

 

---------------------------------

 

AdminState

(1=Online, 2=Offline, 3=Diagnostics, 4=Down) [Online]

Finished configuring attributes.

 

This configuration must be saved (see

config save command) and

activated (see config activate command) before it can take effect.

To discard this configuration use the

config cancel command.

59043-03 A

B-49

Page 171
Image 171
Q-Logic 64 manual Table B-16. Set Config Zoning Parameters, Memory. Refer to FC-SW-2 Compliant