B – Command Line Interface Set Config Command

D

Table B-15. Set Config Threshold Parameters

Parameter

 

Description

 

 

Threshold Monitoring Enabled

Master enable/disable parameter for all

 

events. Enables (True) or disables (False)

 

the generation of all enabled event alarms.

 

The default is False.

CRCErrorsMonitoringEnabled

The event type enable/disable parameter.

DecodeErrorsMonitoringEnabled

Enables (True) or disables (False) the

ISLMonitoringEnabled

generation of alarms for each of the

LoginMonitoringEnabled

following events:

LogoutMonitoringEnabled

„

CRC errors

LOSMonitoringEnabled

„

Decode errors

 

„

ISL connection count

 

„

Device login errors

 

„

Device logout errors

 

„ Loss-of-signal errors

Rising Trigger

The event count above which a rising

 

threshold alarm is logged. The switch will

 

not generate another rising threshold

 

alarm for that event until the count

 

descends below the falling threshold and

 

again exceeds the rising threshold.

Falling Trigger

The event count below which a falling

 

threshold alarm is logged. The switch will

 

not generate another falling threshold

 

alarm for that event until the count

 

exceeds the rising threshold and

 

descends again below the falling

 

threshold.

Sample Window

The period of time in seconds in which to

 

count events.

 

 

 

B-48

59043-03 A

Page 170
Image 170
Q-Logic 64 manual Table B-15. Set Config Threshold Parameters