D

4 – Installation Install Firmware

4.3.3

Using FTP and the CLI to Install Firmware

To install firmware using the CLI when the management workstation does not have an FTP server, do the following:

1.Connect to the switch through the Ethernet or the serial port.

2.Move to the folder or directory that contains the new firmware image file.

3.Establish communications with the switch using the File Transfer Protocol (FTP). Enter one of the following on the command line:

>ftp xxx.xxx.xxx.xxx

or

>ftp switchname

where xxx.xxx.xxx.xxx is the switch IP address, and switchname is the switch name associated with the IP address.

4.Enter the following account name and password:

user:images

password: images

5.Activate binary mode and copy the firmware image file on the switch:

ftp>bin

ftp>put filename

6.Close the FTP session.

ftp>quit

7.Establish communications with the switch using the CLI. Enter one of the following on the command line:

telnet xxx.xxx.xxx.xxx

or

telnet switchname

where xxx.xxx.xxx.xxx is the switch IP address, and switchname is the switch name associated with the IP address.

8.A Telnet window opens prompting you for a login. Enter an account name and password. The default account name and password are (admin, password).

9.Open an Admin session to acquire the necessary authority.

SANbox2 $>admin start

59043-03 A

4-19

Page 77
Image 77
Q-Logic 64 manual Using FTP and the CLI to Install Firmware, Close the FTP session