6 – Removal/Replacement I/O Blades

D

10.Verify the POST results. The I/O blade diagnostic status appears in the dialog. The status should be "Passed".

Hotswap IO blade process successfully completed. Diagnostics has been run on the IO blade in slot 6: Passed

Note: A “Failed” status could indicate a faulty blade or module. Enter the Show POST Log command for more information or contact your authorized maintenance provider.

11.The system checks the I/O blades for matching Zircon processor firmware. If any of the I/O blades are not compatible, an alarm message will be generated indicating that a Zircon firmware mismatch has occurred. To display the alarm messages, enter the Show Alarm command or use the SANbox Manager event browser. Refer to ”Show Command” on page B-63for more information. If a mismatch does occur, contact your authorized maintenance provider.

SANbox2-64 #> show alarm

[9][Wed Jan 16 13:32:19.500 2003]

[A4101][0xdd0072c2.329][IO-1 Zircon firmware mismatch: rev 0.5, should be perhaps rev 0.7]

6-10

59043-03 A

Page 104
Image 104
Q-Logic 64 manual Removal/Replacement I/O Blades