4 – Installation Install Firmware

D

4.3.2

Using the CLI to Install Firmware

To install firmware using the CLI when an FTP server is present on the management workstation, do the following:

1.Connect to the switch through the Ethernet or the serial port and open a Telnet session.

2.Enter the following account name and password:

SANbox2 Login:admin

Password: password

3.To start an admin session, enter the following:

SANbox2 $> admin start

4.Retrieve the firmware file. The device on which the firmware file is stored must be running an FTP server. Enter the following command to retrieve the firmware file from the specified IP address:

SANbox2 (admin) #> image fetch username 10.0.0.254 firmwarefilenametoload firmwarefilenameonswitch

Connected to 10.0.0.254.

Note: If prompted for your password, enter your password (for that IP Address) and press the Enter key.

331 Password required for username. Password:

230 User username logged in. bin

200 Type set to I. verbose

Verbose mode off.

5.Enter the following command to display the list of firmware files:

SANbox2 (admin) #> image list

6.Enter the following command to install the new firmware:

SANbox2 (admin) #>image unpack filename

7.If the new firmware is version 2.0 or later, the new firmware can be salivated without disrupting traffic. Enter the Hotreset command to perform a non-disruptive activation.

SANbox2 (admin) $>hotreset

4-18

59043-03 A

Page 76
Image 76