Q-Logic 64 manual LIP Alpd Alps

Models: 64

1 244
Download 244 pages 38.52 Kb
Page 188
Image 188

B – Command Line Interface Show Command

D

Table B-19. Show Port Parameters (Continued)

 

 

Entry

Description

 

 

FBusy

Number of times the switch sent a F_BSY because Class 2

 

frame could not be delivered within ED_TOV time. Number

 

of class 2 and class 3 fabric busy (F_BSY) frames

 

generated by this port in response to incoming frames.

 

This usually indicates a busy condition on the fabric or

 

N_Port that is preventing delivery of this frame.

Flowerrors

Received a frame when there were no available credits.

FReject

Number of frames from devices that were rejected.

InvalidCRC

Invalid CRC detected.

InvalidDestAddr

Invalid destination address detected.

LIP ALPD ALPS

Number of F7, AL_PS LIPs, or AL_PD (vendor specific)

 

resets, performed.

LIPF7ALPS

This LIP is used to reinitialize the loop. An L_Port,

 

identified by AL_PS, may have noticed a performance

 

degradation and is trying to restore the loop.

LIPF8ALPS

This LIP denotes a loop failure detected by the L_Port

 

identified by AL_PS.

LIPF7F7

A loop initialization primitive frame used to acquire a valid

 

AL_PA.

LIPF8F7

A loop initialization primitive frame used to indicate that a

 

loop failure has been detected at the receiver.

Link Failures

Number of optical link failures detected by this port. A link

 

failure is a loss of synchronization or by loss of signal while

 

not in the offline state. A loss of signal causes the switch to

 

attempt to re-establish the link. If the link is not

 

re-established, a link failure is counted. A link reset is

 

performed after a link failure.

Login

Number of device logins

Logout

Number of device logouts

LoopTimeouts

A two (2) second timeout as specified by FC-AL-2.

LossOfSync

Number of synchronization losses (>100 ms) detected by

 

this port. A loss of synchronization is detected by receipt of

 

an invalid transmission word.

PrimSeqErrors

Primitive sequence errors detected.

 

 

B-66

59043-03 A

Page 188
Image 188
Q-Logic 64 manual LIP Alpd Alps