TROUBLESHOOTING

B. Misfeed in the fusing area

1 Push gently on both ends of the front cover and open it.

4 Lift the fusing unit release levers, to return them to their operating positions.

2 Turn the roller rotating knob in the direction of the arrow.

Roller rotating knob

3 Carefully remove the misfed paper. Lower the fusing unit release levers to allow easier removal.

Fusing unit

Be careful not to tear the

release lever

misfed paper during

 

removal.

Warning

The fusing unit is hot. Do not touch

the fusing unit when removing misfed

 

paper. Doing so may cause a burn or

 

injury.

 

• Do not touch the photoconductive drum

Caution (green portion) when removing the misfed

 

paper. Doing so may damage the drum and

 

cause smudges on copies.

Be careful about unfixed toner on the misfed paper not to soil your hands or clothes.

5 Close the front cover and side cover.

The message " Clear paper path." will be cleared and copying will be possible.

Note

When closing the front cover, gently hold

 

both ends.

When closing the side cover, press on the handle.

If the message does not clear, check again to make sure that no pieces of paper remain.

95

Page 96
Image 96
Sharp MX-M182D, MX-M202D, MX-M232D manual Misfeed in the fusing area, Injury