Hardware Information
Port to the Floppy Disk Drive
This port is intended for the connection of a notebook floppy disk drive. The maximum connection length of the data cable may not exceed 40cm.
Pin no. | Designation | Description | Input/Output |
|
|
|
|
1 | P5V | +5V | Output |
|
|
|
|
2 | INDEX_N | Index hole recognition | Input |
|
|
|
|
3 | P5V | +5V | Output |
|
|
|
|
4 | DS_N0 | Drive 0 selection | Output |
|
|
|
|
5 | P5V | +5V | Output |
|
|
|
|
6 | DCHG_N | Disk change display | Input |
|
|
|
|
7 | n.c. | not connected | - |
|
|
|
|
8 | n.c. | not connected | - |
|
|
|
|
9 | Reserved | reserved | - |
|
|
|
|
10 | MOT_N0 | Activate motor 0 | Output |
|
|
|
|
11 | Reserved | reserved | - |
|
|
|
|
12 | DIR_SL_N | Step motor direction | Output |
|
|
|
|
13 | n.c. | not connected | - |
|
|
|
|
14 | STEP_N | Step motor pulse |
|
|
|
|
|
15 | GND | Ground | - |
|
|
|
|
16 | WR_DAT_N | Write data signal | Output |
|
|
|
|
17 | GND | Ground | - |
|
|
|
|
18 | WR_GAT_N | Enable data signal | Output |
|
|
|
|
19 | Reserved | reserved | - |
|
|
|
|
20 | TRACK_N0 | Track 0 signal | Input |
|
|
|
|
21 | Reserved | reserved | - |
|
|
|
|
22 | WR_PRT_N | Write protection signal | Input |
|
|
|
|
23 | GND | Ground | - |
|
|
|
|
24 | RD_DAT_N | Read Data signal | Input |
|
|
|
|
25 | GND | Ground | - |
|
|
|
|
26 | SIDE_1_N | Page selection | Output |
|
|
|
|
Assignment of the IDE Ports
The primary IDE port is intended for the alternative installation of
2.5” and 3.5” hard disks. 3.5” drives are connected via a 40 pin 2.54mm latching connector, 2.5” drives via a 44 pin 2mm latching connector. The two connectors are connected in parallel. The secondary IDE port is intended for the optional connection of a CD ROM and / or an LS 240 drive. It is adaptable via a 44 pin 2mm latching connector. The maximum connection length of the data cables may not exceed 40cm.
SIMATIC Box PC 620 Manual | |