Siemens 620 appendix Crt / Lcd, Simultan

Models: 620

1 216
Download 216 pages 51.61 Kb
Page 102
Image 102

Configuring the SIMATIC Box PC 620

Entry

 

Meaning

 

 

 

Cardbus /

[Disabled]

Disables the Cardbus / PCMCIA interfaces.

PCMCIA Slot

[Enabled]

The resources are managed by the BIOS

 

 

 

PCI plug and play mechanism.

 

 

 

SafeCard

[Enabled]

On board monitoring functions are enabled.

functions

[Disabled]

No monitoring functions.

 

 

The relevant driver and the application must be started for operation of

 

the monitoring functions.

 

 

 

Legacy USB

[Disabled]

A USB-capable operating system is required to

Support

 

operate a USB keyboard or a USB mouse.

 

 

Setup adjustments can be made with a USB keyboard.

 

[Enabled]

USB keyboard and USB mouse are supported by the

 

 

BIOS. Non-USB capable operating systems can be

 

 

used.

 

 

 

Fan Control

[Enabled]

Fan speed depends on temperature.

 

[Disabled]

Fan always runs at full speed.

 

 

 

CRT / LCD

[LCD Enabled]

All data is output only to the internal LCD,

selection

 

the 15-way VGA port is disabled

 

[CRT Enabled] For maximum resolution the display signals are output

 

 

only to the 15-way VGA port; the LCD interface of the

 

 

VGA controller is disabled.

 

[SIMULTAN]

Both display interfaces are enabled and operate

 

 

simultaneously. Note, however, that the LCD does not

 

 

support all resolutions.

 

 

 

LCD-Screen-

[Normal]

The display window in Text and Graphic modes is not

size

 

expanded to full screen size.

 

[Expanded]

Die volle Bildschirmgröße wird genutzt, auch wenn

 

 

die Auflösung nicht die Pixelgröße des Bildschirms

 

 

hat.

 

 

DSTN Contrast

The contrast of the DSTN displays is set here.

 

Range: 0-255

 

 

 

 

PS/2 Mouse

[Internal]

The PS/2 port is activated.

 

 

This is the default for the Box PC. IRQ 12 is assigned.

 

[Disabled]

The PS/2 port is deactivated, IRQ12 is available.

 

[Autodetect]

It is automatically detected if a mouse is connected.

 

Note:

Invariably, changes to this interface do not come into

 

 

effect until the PC is switched off and on again.

 

 

 

5-14

SIMATIC Box PC 620 Manual

A5E00131465-01

Page 102
Image 102
Siemens 620 appendix Crt / Lcd, Simultan