Sigma LBA-400, LBA-710, LBA-714PC, LBA-300, LBA-712 manual Footnotes, ZMM zoom information, Zom?, Zmm?

Models: LBA-500PC LBA-708 LBA-710 LBA-700 LBA-712 LBA-714PC LBA-400 LBA-300

1 281
Download 281 pages 14.04 Kb
Page 263
Image 263

 

Key

Type

Value Description

 

 

 

 

 

 

 

z = new zoom

 

 

 

+z = zoom in

 

 

 

 

 

:ZOM?

 

 

Returns:

 

 

 

ZOM Zoom=z

 

 

A.5.4.25 ZMM - zoom information

:ZMM?

Returns:

ZMM <index=zoom>;…;<index=zoom>;;

Where:

Index = zoom = list of zooms by index.

The “index” is an integer index used or returned by the ZOM command. The “zoom” is of the form “W x H x R”, W=width, H=height, R=resolution.

For example:

ZMM 0=128x120x4;1=128x120x2;2=128x120x1;3=64x60x1;4=32x30x1;;

A.6 Footnotes

1Commands to set a configuration have the following format: :CCC key=value;key=value;…key=value;key=value; Where:

:= ASCII colon character (0x3A)

CCC= three character command code (case is ignored) followed by space or tab

key =

code for which parameter to set (case ignored)

== ASCII equal sign (0x3D)

value = value to be assigned to the parameter specified by key.

The particular parameter type, format, and allowable range are dependent on which key is being set.

;= ASCII semi-colon character (0x3B)

key =

value can occur in any order.

 

Operator’s Manual