1Request for report on inserted PIN code is activated (on)
3.15AT+CCLK Set Clock and Date
Description | Command | Possible Responses |
Set the real time clock | AT+CCLK=<time> |
of the ME |
|
Show the current | AT+CCLK? |
setting |
|
Show if the command is AT+CCLK=? supported
•_ +CME ERROR: <err>
•_ OK
•_ ERROR
•_ +CCLK: <time>
•_ +CME ERROR: <err>
•_ OK
•_ ERROR
•_ OK
•_ ERROR
Sets the real time clock of the ME. If setting fails in an ME, error +CME ERROR: <err> is returned. Read command returns the current setting of the clock.
<time> | Description |
|
|
string type | Format is “yy/mm/dd,hh:mm:ss±zz”, where characters |
value | indicate year (two last digits), month, day, hour, |
| minutes, seconds and time zone (indicates the difference, |
| expressed in quarters of an hour, between the local time |
| and GMT; range |
| 22:10:00 GMT+2 hours reads “94/05/06,22:10:00+08” |
| NOTE: If the ME does not support time zone information |
| then the three last characters of <time> are not returned |
| by +CCLK? |
3.16AT+CEER Extended Error Report
| Description | Command | Possible Responses |
|
|
|
|
| Request an Extended | AT+CEER | •_ +CEER: <report> |
| Error Report |
| |
|
| •_ OK | |
|
|
| |
|
|
| •_ ERROR |
Owner’s Manual | Rev 1.0 | Page 80 of 80 |