3.3.1.3 VoIP Configuration

This section deals with configuring your TalkSwitch for VoIP

In the “TalkSwitch Profile” section:

TalkSwitch has a built-in SIP Server Proxy / Registrar / Redirect server. This facilitates the configuration and maintenance for multi-branch and teleworker applications. One location needs to be assigned as the SIP Server so that it can manage call requests between VoIP locations and the other locations need to register with the SIP Server location.

To facilitate calling between TalkSwitch locations, we recommend that you use TalkSwitch location codes 250-299 as phone numbers for each of your VoIP Lines. Ensure no duplicate numbers are assigned between any 2 locations.

This TalkSwitch location is the Proxy / Registrar

If this location is going to be the Proxy / Registrar Server, then check this box. When enabled and other SIP devices are registered with this system, then any calls made within the group contact this device to resolve the destination location. Once the destination is resolved, the call is made directly from the source location to the destination location.

24

TalkSwitch User Manual

Page 34
Image 34
Talkswitch 48-CVA manual TalkSwitch Profile section