3.3.5.4 Troubleshooting
The following controls should not be changed unless you are familiar with the effect they will have on TalkSwitch’s operation. If your system does not appear to be functioning properly, please contact your dealer for assistance.
Flash Lengths
Accepted Flash Length:
These options control the allowable Flash length from a Local Extension that TalkSwitch will consider to be an intentional Flash. The range can be adjust- ed to accept anything from 50ms to 1 second. The default range for accepting a Flash signal at a Local Extension is between 200 ms and 800 ms. Most phones emit a 600 ms Flash signal when the ‘Flash’ or ‘Link’ button is pressed.
Transmitted Flash Length:
This option controls the transmitted Flash length from TalkSwitch to the Telephone Company lines. TalkSwitch emits a Flash when forwarding or bridging calls using the
3.0 | Configuring TalkSwitch |