EF4270 Emulation Commands

Upside-Down Off

Turns off upside-down printing.

Hexadecimal Decimal ASCII

1B 52

27 82

ESC R

Upside-Down Print

Starts upside-down printing. Available for both journal and validation printing. Lines are printed in the order they are received from the host. The first line of data is the last line of text after the slip is turned right-side up for reading.

Hexadecimal Decimal ASCII

1B 55

27 85

ESC U

Rotate Font 90 Degrees Clockwise or Cancel Rotated Print

Enables printing with characters rotated 90 degrees clockwise. Keep the following in mind when working with rotated characters

When the line buffer is empty, rotated font can be set or cancelled. When the print buffer is not empty, the command has no effect.

The print zone width is 3.024 inches for rotated characters (2.88 inches for upright characters).

Rotated and upright characters cannot be mixed on the same line.

Double-high/wide characters can be used in any combination with rotated print.

The following commands have no effect while rotated print is enabled.

Pitch Selection(1B 50 n)

Character Set (1B 21 n)

Setup Parameters (19 n)

For print to be rotated clockwise, the characters must be inverted as well as rotated.

Hexadecimal

Decimal

ASCII

Value of n n

1B 7D n n

27 123

ESC }

Odd = rotation enabled.

 

 

 

Even = rotation cancelled.

9–18

3255 4073–002