Diagnostics and Print Tests

Continuous Slip Printing

This test prints a slip, stopping each time the end of the slip is sensed and continuing when a new slip is inserted. The printout includes all ROM CRC, internal switch pack, and configuration information (same as the Print Configuration Information test). See the sample printout later in this section.

1.Turn the printer off.

2.Turn the printer to the back to access the DIP switches and write down the current switch settings.

3.Set the DIP switches to the following settings:

Switch

Switch

Switch

Switch

Switch

Switch

Switch

Switch

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

ON

OFF

N/A

ON

ON

OFF

N/A

N/A

4.Turn the printer back on.

The Slip In LED flashes until a slip is inserted. When the slip is positioned correctly, the Slip In LED is on steady.

5.Press the Paper Feed button.

The printer prints the slip. When the printer senses the end of the slip, printing stops.

6.Remove the slip and insert a new one to continue the test.

OR

Turn the printer off to stop the test.

7.Turn the printer off and reset the DIP switches to what they were when you started.

For normal operation settings, see “Setting Switches” in section 5.

8.Turn the printer back on to begin normal operation.