Diagnostics and Print Tests

Exit Data Scope Mode

1.Turn the printer off.

2.Turn the printer to the back to access the DIP switches and write down the current switch settings.

3.Set the DIP switches to the following settings:

Switch

Switch

Switch

Switch

Switch

Switch

Switch

Switch

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

4.Turn the printer back on to take the printer out of Data Scope mode.

The red Paper Status LED blinks once to indicate that the printer is out of Data Scope mode.

5.Turn the printer off and reset the DIP switches to what they were when you started.

6.For normal operation settings, see “Switch Settings” in section 5.

7.Turn the printer back on.

Enabling or Disabling the Cover Open Switch

Use this procedure to enable or disable the cover open switch. The cover open switch is optional, and may not be available on all printers.

Note: The EFP9800 FLASHADMIN software utility can also be used for enabling or disabling the cover open switch. This utility is included in the EFP9800-SW1 style package.

Caution

The DIP switches are set at the factory to predetermined settings. Change the settings carefully to avoid changing other functions.

Note: Secure the roller assembly in a closed position to eliminate the nuisance noise form occurring when the receipt assembly is not being used.

3255 4073–002

3–21

Page 59
Image 59
Unisys EFP9800 manual Enabling or Disabling the Cover Open Switch, Diagnostics and Print Tests Exit Data Scope Mode