Printer Configuration and Adjustment 87
Changing Printer Settings
Table 7 • Print Settings (Continued)
Backfeed | This parameter sets when label backfeed occurs after a label is removed in some print | ||
Sequence | modes. It has no effect in Rewind mode. This setting is superseded by ~JS when received | ||
| as part of a label format. |
|
|
| Accepted values: | • AFTER (backfeed occurs immediately after the last | |
|
|
| label is completed) |
|
| • | OFF (no backfeed) |
|
| • BEFORE (backfeed occurs before the forward motion | |
|
|
| of the first label) |
|
| • | DEFAULT |
| Related ZPL command(s): | ~JS | |
| SGD command used: | none | |
| Control panel menu item: | ||
| Printer web page: | View and Modify Printer Settings > Advanced Setup > | |
|
|
| Backfeed |
|
| ||
Label Top | This parameter adjusts the print position vertically on the label. Positive numbers adjust the | ||
Position | label top position farther down the label (away from the printhead) by the specified number | ||
| of dots. Negative numbers adjust the position up the label (toward the printhead). | ||
| Accepted values: | ||
| Related ZPL command(s): | ^LT | |
| SGD command used: | none | |
| Control panel menu item: | ||
| Printer web page: | View and Modify Printer Settings > General Setup > | |
|
|
| Label Top |
|
| ||
Label Left | If necessary, shift the print position horizontally on the label. Positive numbers move the left | ||
Position | edge of the image toward the center of the label by the number of dots selected, while | ||
| negative numbers move the left edge of the image toward the left edge of the label. | ||
| Accepted values: | ||
| Related ZPL command(s): | ^LS | |
| SGD command used: | none | |
| Control panel menu item: | ||
| Printer web page: | View and Modify Printer Settings > Advanced Setup > | |
|
|
| Left Position |
|
| ||
Head Test | The printer periodically performs a test of the printhead functionality. This parameter | ||
Count | establishes how many labels are printed between these internal tests. | ||
| Accepted values: | 0000 (disables the test) to 9999 | |
| Related ZPL command(s): | ^JT | |
| SGD command used: | none | |
| Control panel menu item: | ||
| Printer web page: | View and Modify Printer Settings > Advanced Setup > | |
|
|
| Head Test Count |
|
|
|
|
7/3/13 |