90Printer Configuration and Adjustment Changing Printer Settings

Table 8 • Maintenance and Diagnostic Tools (Continued)

Non-Resettable

The non-resettable counter gives the total length of media that the printer has printed.

Counter

You can use firmware commands to change the unit of measure for this counter.

 

Related ZPL command(s):

^MA (for changing unit of measure)

 

SGD command used:

none

 

Control panel menu item:

NONRESET CNTR on page 24

 

Printer web page:

none

 

 

User-Controlled

Two user-controlled counters give the total length of media that the printer has printed

Counters

since the last time the counter was reset. You can use firmware commands to change the

 

unit of measure and reset the counters.

 

Related ZPL command(s):

^MA (for changing unit of measure)

 

 

~RO (for resetting counters)

 

SGD command used:

odometer.media_marker_count1

 

 

odometer.media_marker_count2

 

Control panel menu item:

RESET CNTR1 on page 24

 

 

RESET CNTR2 on page 24

 

Printer web page:

none

 

 

Print Counter

Prints a label that lists the odometer readings for the following:

Readings

the non-resettable counter

 

the two user-controlled counters

the Early Warning for Maintenance counters, which indicate when the printhead was last cleaned and the printhead life (If the Early Warning for Maintenance feature is disabled, the counters related to it do not print.)

Related ZPL command(s): ~HQ

SGD command used: none

Control panel menu item: PRINT METERS on page 24

Printer web page: none