92Printer Configuration and Adjustment Changing Printer Settings

Table 8 • Maintenance and Diagnostic Tools (Continued)

Power-Up Action Set the Power-Up Action

Set the action for the printer to take during the power-up sequence.

CALIBRATE adjusts sensor levels and thresholds, determines the label length, and feeds the media to the next web.

FEED—feeds the labels to the first registration point.

LENGTH determines the label length using current sensor values, and feeds the media to the next web.

NO MOTION tells the printer not to move the media. You must manually ensure that the web is positioned correctly, or press feed to position the next web.

SHORT CAL sets the media and web thresholds without adjusting sensor gain, determines the label length, and feeds the media to the next web.

Accepted values:

CALIBRATE

FEED

LENGTH

NO MOTION

SHORT CAL

Related ZPL command(s): ^MF

SGD command used: none

Control panel menu item: MEDIA POWER UP on page 29

Printer web page: View and Modify Printer Settings > Calibration

Head-Close

Set the Head-Close Action

 

Action

Set the action for the printer to take when you close the printhead.

 

CALIBRATE adjusts sensor levels and thresholds, determines the label length, and

 

feeds the media to the next web.

 

 

FEED—feeds the labels to the first registration point.

 

LENGTH determines the label length using current sensor values, and feeds the

 

media to the next web.

 

 

NO MOTION tells the printer not to move the media. You must manually ensure

 

that the web is positioned correctly, or press feed to position the next web.

 

SHORT CAL sets the media and web thresholds without adjusting sensor gain,

 

determines the label length, and feeds the media to the next web.

 

Accepted values:

CALIBRATE

 

FEED

 

LENGTH

 

NO MOTION

 

SHORT CAL

Related ZPL command(s): ^MF

SGD command used: none

Control panel menu item: HEAD CLOSE on page 30

Printer web page: View and Modify Printer Settings > Calibration

P1056468-002

7/3/13