94Printer Configuration and Adjustment Changing Printer Settings
Table 8 • Maintenance and Diagnostic Tools (Continued)
Media and | Calibrate the printer to adjust the sensitivity of the media and ribbon sensors. | ||
Ribbon Sensor | For complete instructions on how to perform a calibration procedure, see Calibrate the | ||
Calibration | |||
| Accepted values: | N/A | |
| Related ZPL command(s): | ~JC | |
| SGD command used: | none | |
| Control panel menu item: | ||
| Control panel key(s): | Hold PAUSE + FEED + CANCEL for 2 seconds to | |
|
| initiate calibration. | |
| Printer web page: | The calibration procedure cannot be initiated through | |
|
| the web pages. See the following web page for | |
|
| settings that are set during sensor calibration: | |
|
|
| View and Modify Printer Settings > Calibration |
|
|
| Important • Do not change these settings |
|
|
| unless you are told to do so by Zebra |
|
|
| Technical Support or by an authorized service |
|
|
| technician. |
|
| ||
Communication | Use this diagnostics tool to cause the printer to output the hexadecimal values for all | ||
Diagnostics Mode | data received by the printer. |
|
|
| For more information, see Communication Diagnostics Test on page 155. | ||
| Accepted values: | • | DISABLED |
|
| • | ENABLED |
| Related ZPL command(s): | ~JD to enable, ~JE to disable | |
| SGD command used: | none | |
| Control panel menu item: | ||
| Printer web page: | N/A | |
|
| ||
Format | Selects the bitmap scaling factor. The first number is the original dots per inch (dpi) | ||
Conversion | value; the second, the dpi to which you would like to scale. | ||
| Accepted values: | • | NONE |
|
| • | 150 → 300 |
|
| • | 150 → 600 |
|
| • | 200 → 600 |
|
| • | 300 → 600 |
| Related ZPL command(s): | none | |
| SGD command used: | none | |
| Control panel menu item: | ||
| Printer web page: | none | |
|
|
|
|