Command Reference Guide E1 Interface Configuration Command Set
61200990L1-35E Copyright © 2005 ADTRAN 511
clock source [internal | line | through]
Use the clock source command to configure the source timing used for the interface. Use the no form of
this command to return to the default value.
Syntax Description
internal Configures the unit to provide clocking using the internal oscillator.
line Configures th e uni t to re co ver c lock i ng from th e E1 circ uit.
through Configures the unit to recover clocking from the circuit connected to the G.703
interface.
Default Values
By default, the unit is configured to recover clocking from the primary circuit.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.
Command History
Release 5.1 Command was introduced.
Functional Notes
When operating on a circuit tha t is providing timing , setting the clock sourc e to line can avoid erro rs such
as Clock Slip Seconds (CSS).
Usage Examples
The following example configures the unit to recover clocking from the primary circuit:
(config)#interface e1 1/1
(config-e1 1/1)#clock source line