Compatibility Language - F

Compatibility

Command

OVSET <n>

POL 0 1

PON 0 1

RELAY 0 1

RLYPON 0 1

ROM?

RST

SENS:CURR :RANG <n>

SENS:PROT :STAT 0 1

SENS:SWE :POIN <n>

SENS:SWE :TINT <n>

SRQ 0 1

STS?

SYST:LANG

Table F-2. COMPatibility Commands (continued)

Description

This command programs the overvoltage protection. See Table 8-3 for the programming range of this command.

Initial condition: MAX

Only applies to units with Option 760. This command sets the polarity of the output relays to either normal (1) or inverted (0). Initial condition: POL 1

This command enables (1) or disables (0) SRQ at power-on. Initial condition: last programmed value

Only applies to units with Relay Option 760. This command opens (0) or closes (1) the output relays without affecting the programmed output state of the unit.

Initial condition: RELAY 1

Only applies to units with Relay Option 760. This command opens (0) or closes (1) the output relays at power-on without affecting the programmed output state of the unit.

Initial condition: RLYPON 1

This command returns the ROM version of the dc source. Data Representation: AAA AAA

This command resets the dc source if the output is disabled by the output protection circuits.

This command sets the current measurement range of the dc source. See Table 8-3 for the programming range.

Initial condition: MAX

This command enables/disables the open sense detect feature. Initial condition: 1

This command defines the number of data points in a measurement sweep.

Initial condition: 32

This command defines the time period between measurement samples.

Initial condition: 15.6 s.

These commands enable or disable the dc source’s ability to request service from the controller for fault conditions. UNMASK defines which conditions are defined as faults. Initial condition: SRQ 0

This command reads the contents of the status register, which maintains the present status of the dc source.

Data Representation: ZZZZD

This command causes the alternate language to become active and to be stored in nonvolatile memory. In this case, the commands are equivalent. After being shut off, the dc source will resume in the last-selected language when power is restored. The parameter must be either COMP or SCPI.

Similar SCPI

Command

VOLT:PROT

OUTP:REL:POL 01

PSC 0 1

OUTP:REL 0 1

RCL 0

*IDN?

OUTP:PROT:CLE

SENS:CURR:RANG

SENS:PROT:STAT

SENS:SWE:POIN

SENS:SWE:TINT

*SRE

STAT:OPER:COND?

STAT:QUES:COND?

*ESE?

SYST:LANG

179

Page 179
Image 179
Agilent Technologies 66111A, D, 66311B, 66309B manual 179

66111A, 66309B, 66311B, D specifications

Agilent Technologies D,c,83440b is an advanced electronic measurement solution designed for engineers and scientists who require precise and reliable performance in their testing environments. This modular test system offers a comprehensive suite of features that cater to a wide range of applications, from high-frequency testing to complex signal analysis.

One of the main features of the D,c,83440b is its impressive frequency range, allowing users to conduct tests across a wide spectrum of signals. The system is capable of handling frequencies up to 26.5 GHz, making it ideal for RF and microwave applications. This broad range ensures that users can work with a variety of devices, including communication systems, radar, and satellite technology.

In addition to its frequency capabilities, Agilent Technologies has engineered the D,c,83440b with exceptional dynamic range and low noise figures. This ensures that even the smallest signals can be accurately measured, allowing for greater precision in testing. The full spectrum analysis feature enables users to capture transient events and analyze them in real-time, which is crucial for troubleshooting and performance evaluations.

The D,c,83440b is built on a modular platform, allowing users to customize their systems according to specific testing needs. This modularity not only enhances flexibility but also simplifies maintenance and upgrades. Users can easily swap out different modules without the need for extensive system reconfiguration, which can significantly reduce downtime in testing environments.

Another standout characteristic of the D,c,83440b is its user-friendly interface. With a large, high-resolution display and intuitive controls, engineers can quickly navigate through settings and data, streamlining the testing process. This ease of use is complemented by powerful software solutions that can automate test sequences, aiding in efficiency and accuracy.

The integration of advanced digital signal processing technologies further enhances the capabilities of the D,c,83440b. These technologies enable more sophisticated measurements and improved signal integrity, which is essential for modern communication systems.

In summary, the Agilent Technologies D,c,83440b is a multifaceted electronic measurement solution that boasts a wide frequency range, excellent dynamic range, modular design, and user-friendly interface. This combination of features makes it suitable for various applications, ensuring that engineers and scientists have the tools they need to succeed in their testing and measurement endeavors.