8 – Language Dictionar y
98
Table 8-1. Subsystem Commands Syntax (continued)
:PROTection
[:LEVel] <n> Sets the overvoltage protection threshold
:STATe <bool> Enables/disables overvoltage protection
VOLTage2
[:LEVel]
[:IMMediate][:AMPLitude] <n> Sets the output2 voltage level
:TRIGgered [:AMPLitude] <n> Sets the triggered output2 voltage level
STATus
:PRESet Presets all enable and transition registers to power-on
:OPERation
[:EVENt]? Returns the value of the event register
:CONDition? Returns the value of the condition register
:ENABle <n> Enables specific bits in the Event register
:NTRansition<n> Sets the Negative transition filter
:PTRansition<n> Sets the Positive transition filter
:QUEStionable
[:EVENt]? Returns the value of the event register
:CONDition? Returns the value of the condition register
:ENABle <n> Enables specific bits in the Event register
:NTRansition<n> Sets the Negative transition filter
:PTRansition<n> Sets the Positive transition filter
SYSTem
:ERRor? Returns the error number and error string
:LANGuage <language> Se ts the programming language (SCPI | COMP)
:VERSion? Returns the SCPI version number
TRIGger
:SEQuence2 | :ACQuire
[:IMMediate] Triggers the measurement immediately
:COUNt
:CURRent <n> Sets the number of sweeps per current measurement
:DVM <n> Sets the number of sweeps per DVM measurement
:VOLTage <n> Sets the number of sweeps per voltage measurement
:HYSTeresis
:CURRent <n> Qualifies the trigger when measuring current
:DVM <n> Qualifies the trigger when making DVM measurements
:VOLTage <n> Qualifies the trigger when measuring voltage
:LEVel
:CURRent <n> Sets the trigger level for measuring current
:DVM <n> Sets the trigger level when making DVM measurements
:VOLTage <n> Sets the trigger level for measuring voltage
:SLOPe
:CURRent <slope> Sets the triggered current slope (POS | NEG | EITH)
:DVM <slope> Sets the triggered DVM measurement slope (POS | NEG | EITH)
:VOLTage <slope> Sets the triggered voltage slope (POS | NEG | EITH)
:SOURce <source> Sets the trigger source (BUS | INT)
[:SEQuence1 | :TRANsient]
[:IMMediate] Triggers the output immediately
:SOURce <source> Sets the trigger source (BUS)
:SEQuence1
:DEFine TRANsient Sets or queries the SEQ1 name
:SEQuence2
:DEFine ACQuire Sets or queries the SEQ2 name