Agilent Technologies 66309B manual TRIGgerSEQuence2HYSTeresisDVM TRIGgerACQuireHYSTeresisDVM, 130

Models: 66111A 66309B 66311B D

1 190
Download 190 pages 33.49 Kb
Page 130
Image 130

8 – Language Dictionary

TRIGger:SEQuence2:HYSTeresis:DVM

TRIGger:ACQuire:HYSTeresis:DVM

Agilent 66311D/66309D only

This command defines a band around the trigger level through which the input signal must pass before a DVM measurement can occur. The band limit above and below the trigger level is one half of the hysteresis value added to or subtracted from the trigger level. For a positive trigger to occur, the excursion of an input signal in the positive direction must start below the lower hysteresis band limit and pass through the upper hysteresis band limit. For a negative trigger to occur, the excursion of an input signal in the negative direction must start above the upper hysteresis band limit and pass through the lower hysteresis band limit.

Command Syntax

TRIGger:SEQuence2:HYSTeresis:DVM<NRf+>

 

TRIGger:ACQuire:HYSTeresis:DVM<NRf+>

Parameters

0 to MAX (see table A-3)

Unit

V (volts)

*RST Value

0

Examples

TRIG:SEQ2:HYST:DVM 0.5 TRIG:ACQ:HYST:DVM 0.5

Query Syntax

TRIGger:SEQuence2:HYSTeresis:DVM?

 

TRIGger:ACQuire:HYSTeresis:DVM?

Returned Parameters

<NR3>

Related Commands

TRIG:SEQ2:LEV:DVM

TRIGger:SEQuence2:HYSTeresis:VOLTage

TRIGger:ACQuire:HYSTeresis:VOLTage

This command defines a band around the trigger level through which the signal must pass before an internal measurement can occur. The band limit above and below the trigger level is one half of the hysteresis value added to or subtracted from the trigger level.

For a positive trigger to occur, the excursion of an output waveform in the positive direction must start below the lower hysteresis band limit and pass through the upper hysteresis band limit. For a negative trigger to occur, the excursion of an output waveform in the negative direction must start above the upper hysteresis band limit and pass through the lower hysteresis band limit.

Command Syntax

TRIGger:SEQuence2:HYSTeresis:VOLTage<NRf+>

 

TRIGger:ACQuire:HYSTeresis:VOLTage<NRf+>

Parameters

0 to MAX (see table 8-3)

Unit

V (volts)

*RST Value

0

Examples

TRIG:SEQ2:HYST:VOLT 2

 

TRIG:ACQ:HYST:VOLT 2

Query Syntax

TRIGger:SEQuence2:HYSTeresis:VOLTage?

 

TRIGger:ACQuire:HYSTeresis:VOLTage?

Returned Parameters

<NR3>

Related Commands

TRIG:SEQ2:HYST:CURR TRIG:SEQ2:LEV:VOLT

130

Page 130
Image 130
Agilent Technologies 66309B, 66311B, 66111A manual TRIGgerSEQuence2HYSTeresisDVM TRIGgerACQuireHYSTeresisDVM, 130

66111A, 66309B, 66311B, D specifications

Agilent Technologies D,c,83440b is an advanced electronic measurement solution designed for engineers and scientists who require precise and reliable performance in their testing environments. This modular test system offers a comprehensive suite of features that cater to a wide range of applications, from high-frequency testing to complex signal analysis.

One of the main features of the D,c,83440b is its impressive frequency range, allowing users to conduct tests across a wide spectrum of signals. The system is capable of handling frequencies up to 26.5 GHz, making it ideal for RF and microwave applications. This broad range ensures that users can work with a variety of devices, including communication systems, radar, and satellite technology.

In addition to its frequency capabilities, Agilent Technologies has engineered the D,c,83440b with exceptional dynamic range and low noise figures. This ensures that even the smallest signals can be accurately measured, allowing for greater precision in testing. The full spectrum analysis feature enables users to capture transient events and analyze them in real-time, which is crucial for troubleshooting and performance evaluations.

The D,c,83440b is built on a modular platform, allowing users to customize their systems according to specific testing needs. This modularity not only enhances flexibility but also simplifies maintenance and upgrades. Users can easily swap out different modules without the need for extensive system reconfiguration, which can significantly reduce downtime in testing environments.

Another standout characteristic of the D,c,83440b is its user-friendly interface. With a large, high-resolution display and intuitive controls, engineers can quickly navigate through settings and data, streamlining the testing process. This ease of use is complemented by powerful software solutions that can automate test sequences, aiding in efficiency and accuracy.

The integration of advanced digital signal processing technologies further enhances the capabilities of the D,c,83440b. These technologies enable more sophisticated measurements and improved signal integrity, which is essential for modern communication systems.

In summary, the Agilent Technologies D,c,83440b is a multifaceted electronic measurement solution that boasts a wide frequency range, excellent dynamic range, modular design, and user-friendly interface. This combination of features makes it suitable for various applications, ensuring that engineers and scientists have the tools they need to succeed in their testing and measurement endeavors.