Block Display, Hold Queuing

BHI – Multiple monitor alarm block, all alarms are queued and displayed on monitors with no existing alarms. Monitors display and hold the first alarmed contacts. Alarms are removed from the queue when the alarm closure is restored (Instant).

BHI A – Multiple monitor alarm block, all alarms are queued and displayed on monitors with no existing alarms. Monitors display and hold the first alarmed contacts. Alarms are removed from the queue when the alarm closure is restored or the user clears the alarm (Instant or Manual).

BHA – Multiple monitor alarm block, all alarms are queued and displayed on monitors with no existing alarms. Monitors display and hold the first alarmed contacts. Alarms are removed from the queue 20 seconds after the alarm closure is restored (Automatic).

BHA A – Multiple monitor alarm block, all alarms are queued and displayed on monitors with no existing alarms. Monitors display and hold the first alarmed contacts. Alarms are removed from the queue 20 seconds after the alarm closure is restored or when the user clears the alarm (Automatic or Manual).

BHM – Multiple monitor alarm block, all alarms are queued and displayed on monitors with no existing alarms. Monitors display and hold the first alarmed contacts. Alarms are removed from the queue only when the operator clears the alarm (Manual).

Dual Display, Hold and Sequence Queuing

DHI/DSI – Two alarm monitors, the first alarm is displayed on the Hold (DHI) monitor, and all subsequent alarms are queued and sequenced on the Sequence (DSI) monitor. Alarms are removed from the Sequence monitor queue when the alarm closure is cleared. When the alarm closure on the Hold monitor is cleared, the oldest alarm contact on the Sequence monitor is moved to the Hold monitor and removed from the Sequence monitor (Instant).

DHI A/DSI A – Two alarm monitors, the first alarm is displayed on the Hold (DHI) monitor, and all subsequent alarms are queued and sequenced on the Sequence (DSI) monitor. Alarms are removed from the Sequence monitor queue when the alarm closure is cleared instantly or when the operator clears the alarm. When the alarm closure on the Hold monitor is cleared instantly, or cleared by the operator, the oldest alarm on the Sequence monitor is moved to the Hold monitor and removed from the Sequence monitor (Instant or Manual).

DHA/DSA – Two alarm monitors, the first alarm is displayed on the Hold (DHI) monitor. All subsequent alarms are queued and sequenced on the Sequence (DSI) monitor. All subsequent alarms are queued and sequenced on the Sequence monitor. Alarms are removed from the Sequence monitor queue 20 seconds after the alarm clears. When the alarm closure on the Hold monitor is clears, and 20 seconds has expired, the oldest alarm contact on the Sequence monitor is moved to the Hold monitor and removed from the Sequence monitor (Automatic)

DHA A/DSA A – Two alarm monitors, the first alarm is displayed on the Hold (DHI) monitor, and all subsequent alarms are queued and sequenced on the Sequence (DSI) monitor. All subsequent alarms are queued and sequenced on the Sequence monitor. Alarms are removed from the Sequence monitor queue 20 seconds after the alarm closure is cleared or when the operator clears the alarm. When the alarm closure on the Hold monitor is cleared and 20 seconds has expired, or the alarm is cleared by the operator, the oldest alarm on the Sequence monitor is moved to the Hold monitor and removed from the Sequence monitor (Automatic or Manual).

DHM/DSM – Two alarm monitors, the first alarm is displayed on the Hold (DHI) monitor, and all subsequent alarms are queued and sequenced on the Sequence (DSI) monitor. All subsequent alarms are queued and sequenced on the Sequence monitor. Alarms are removed from the Sequence monitor queue only when the operator clears the alarm. When the alarm on the Hold monitor is cleared, the oldest alarm on the Sequence monitor is moved to the Hold monitor and removed from the Sequence monitor (Manual).

MEGAPOWER CPU ADMINISTRATOR’S GUIDE

8200-0421-03, REV. G

77 of 82

Page 79
Image 79
American Dynamics ADMPCPU manual Block Display, Hold Queuing, Dual Display, Hold and Sequence Queuing