1.10Scanner Unit

(1)Unplug the LD PCB harness (scanner flat cable) connector (6P), and polygon harness (5P).

(2)Remove the beam from the body by loosening the screws.

(3)Remove the scanner unit from the body by loosening the screws.

Caution: Do not disassemble the scanner unit, it can be only adjusted at the factory.

Scanner unit

ScrewsScrews

Beam

Polygon harness 5P

Scanner flat cable 6P

Figure 4.8

1.11Cartridge Stopper Assy

(1)Loosen 4 screws and remove the scanner mount plate in the direction of the arrow (the ground leaf spring is also released at the same time.)

(2)Release the hook by bending the arm of the cartridge stopper assy ( A ), slide the cartridge stopper assy to the left ( B ) and the remove the cartridge stopper assy ( C ).

Rear

Ground leaf spring

Screws

Right side

 

Scanner mount plate

Left side

Front

Cartridge stopper assy

Figure 4.9

 

Cartridge stopper assy

 

Scanner mount plate

B

 

 

C

A

Figure 4.10

IV - 5

Page 149
Image 149
Brother HL-1260 service manual Scanner Unit