M-7

"CHECK XX TRAY " is displayed even if a paper-loaded cassette is mounted (or even if a paper is set on MP tray) XX is MP/T1/T2

Possible cause

Step

Check

Result

Remedy

 

 

 

 

 

Mis-operation

1

Is the paper feed mode set correctly?

No

Set paper feed mode

 

 

 

 

correctly.

 

 

 

 

 

Actuator

2

Does the actuator for the paper empty sensor

No

Reassemble or replace the

 

 

operate smoothly?

 

actuator.

 

 

 

 

 

Paper empty

3

Does the voltage of P5-3 (or P5-14) in the

No

Replace the paper feed/size-

sensor

 

Paper feeder PCB connector rise from 0V to

 

sw PCB assy or feed flat

Feed flat cable

 

5V when the paper empty sensor is covered?

 

cable .

 

 

 

 

 

Paper feed flat

4

Does the voltage of P3-3 (or P3-14) in the main

No

Replace the feed flat cable.

cable

 

PCB connector rise from 0V to 5V when the

 

 

 

 

Replace the main PCB assy.

Main PCB

 

paper empty sensor is covered?

Yes

 

 

 

 

 

M-8 "14 NO CARTRIDGE " is displayed

Possible cause

Step

Check

Result

Remedy

 

 

 

 

 

EP-ED cartridge

1

Is an EP-ED cartridge installed correctly?

No

Install the EP-ED cartridge

 

 

 

 

correctly.

 

 

 

 

 

Transfer unit

2

Is the electrode of the transfer unit dirty?

Yes

Clean the electrode of the

electrode

 

 

 

transfer unit.

 

 

 

 

 

High-voltage

3

Is the voltage of P4-13 in the high-voltage

Yes

Replace the high-voltage

power supply

 

power supply PCB connector higher than that

 

power supply PCB assy.

PCB

 

of P4-11 over 2.5V?

 

 

 

 

 

 

 

HV harness

4

Is the voltage of P6-13 in the main PCB

Yes

Replace the HV harness.

 

 

connector higher than that of P6-11 over 2.5V?

 

 

Main PCB

 

No

Replace the main PCB assy.

 

 

 

 

 

 

 

VI - 3

Page 155
Image 155
Brother HL-1260 service manual no Cartridge is displayed