I-13

Faulty registration

Possible cause

Step

Check

Result

Remedy

 

 

 

 

 

Top margin

1

Does self test printing have no problem?

Yes

Check again the top margin

setting error

 

 

 

setting in the printing data.

 

 

 

 

 

Paper load in

2

Is over-amount of paper than specified load

Yes

Reduce the paper load below

the cassette

 

on the cassette?

 

the specified limit.

 

 

 

 

 

Paper failure

3

Does print quality improve when

Yes

Use recommended paper.

 

 

recommended paper is used?

 

 

 

 

 

 

 

Paper failure

4

Is paper curled?

Yes

Use recommended fresh

 

 

 

 

paper without curl.

 

 

 

 

 

Improper Y

5

Does print quality improve when Y offset

Yes

Ajust Y offset setting to an

offset setting

 

setting is changed?

 

appropriate value.

 

 

 

 

 

Jam remove

6

Is the jam remove cover deformed?

Yes

Replace the jam remove

cover failure

 

 

 

cover.

 

 

 

 

 

Failure in

7

Does the regist sensor actuator operate

No

Reassemble the actuator

regist sensor

 

smoothly?

 

and, if the problem is not

actuator motion

 

 

 

resolved, replace the actuator.

 

 

 

 

 

Regist sensor

8

Is the voltage at the pin 5 of the connector P3

No

Replace the paper feed/size-

failure

 

of the main PCB 5V when no paper passes

 

sw PCB assy or the harness

 

 

and 0V when paper passes?

 

and, if the problem remains,

 

 

 

 

replace the main PCB assy.

Paper feed

 

 

 

 

 

 

Yes

Replace the paper feed roller

roller failure

 

 

 

assy.

 

 

 

 

 

I-14

Poor fixing

Possible cause

Step

Check

Result

Remedy

 

 

 

 

 

Fixing unit release

1

Is the fixing unit release spacer removed?

No

Remove the fixing unit

spacer not

 

 

 

release spacer.

removed

 

 

 

 

 

 

 

 

 

MEDIA TYPE

2

Is the MEDIA TYPE set to TRANSPARENCY?

Yes

Set the MEDIA TYPE to

setting

 

 

 

REGULAR or THICK PAPER.

 

 

 

 

 

Paper failure

3

Is thick paper over than 36lb (135g/m2) used?

Yes

Instruct the user to use the

 

 

 

 

paper whose thickness is

 

 

 

 

less than the recommended

 

 

 

 

value.

 

 

 

 

 

Thermistor

4

Is the voltage at the pin 3 of the connector

No

Replace the fixing unit.

failure

 

P11 of the main PCB is controlled within

 

 

Fixing unit

 

1.80±0.10V during continuous printing?

 

 

 

Yes

Replace the fixing unit.

 

 

failure

 

 

 

 

 

 

 

 

 

VI - 10

Page 87
Image 87
Brother HL-1260 service manual Poor fixing, Faulty registration