M-4

Malfunction of control panel switches.

Possible cause

Step

Check

 

Result

Remedy

 

 

 

 

 

Mis-operation

1

Are the switchs operated according to the

No

Operate the switches

 

 

operation manual?

 

 

 

correctly following the

 

 

 

 

 

 

operation manual.

 

 

 

 

 

Switch

2

When a switch is pressed,does the voltage of

Yes

Replace the Main PCB assy.

Control panel

 

the following signals change from 5V to 0V?

 

 

 

 

 

 

No

Replace the control panel

PCB

 

Signal

Main PCB

Panel PCB

 

 

unit or the switch flat cable.

 

 

 

 

 

SW8(SEL)

P1-8

---P1-14

 

 

 

 

 

Switch flat cable

 

SW7(MODE/EMULATION)

P1-10

---P1-12

 

 

 

SW6(FONT/ECONOMY)

P1-12

---P1-10

 

 

Main PCB

 

SW5(FORM FEED/FEEDER)

P1-14

--- P1-8

 

 

 

SW4(SET/COPY)

P1-16

--- P1-6

 

 

 

 

SW3(CONTINUE/SHIFT)

P1-18

--- P1-4

 

 

 

 

SW2(DOWN/RESET)

P1-20

--- P1-2

 

 

 

 

SW1(UP/TEST)

P1-21

--- P1-1

 

 

 

 

 

 

 

 

 

M-5

Malfunction of buzzer

Possible cause

Step

Check

Result

Remedy

 

 

 

 

 

Operational

1

Is the "Buzzer on mode "selected according

No

Set the buzzer on mode.

error

 

to the operation manual?

 

 

 

 

(To alternate the buzzer on/off mode selection,

 

 

 

 

press the MODE switch and select the

 

 

 

 

"Advanced mode".)

 

 

 

 

 

 

 

Main PCB

2

Check the buzzer signal with a oscilloscope.

Yes

Replace the main PCB assy.

 

 

Is the pulse of 4KHz output?

 

 

Buzzer

 

No

Replace the main PCB assy.

 

 

 

 

 

 

 

M-6

"12 COVER OPEN" is displayed even if the upper cover is closed

Possible cause

Step

Check

Result

Remedy

 

 

 

 

 

Upper cover

1

Does the upper cover hook press the actuator

No

Replace the upper cover assy.

Main PCB

 

of the interlock switch on the main PCB

 

 

 

 

 

 

correctly when upper cover is closed?

Yes

Replace the main PCB assy.

 

 

 

 

 

VI - 2

Page 154
Image 154