5.19.2 Enabling /Disabling Ports

Chapter 5: Local Management

5.19.2 Enabling /Disabling Ports

To enable or disable one or more ports, proceed as follows:

1.Use the arrow keys to highlight the CONNECTOR # field.

2.Use the SPACE bar to step to the number of the connector containing the network(s) to be enable or disabled.

3.Use the arrow keys to highlight the MODE PORT STAT. field of the network being enabled or disabled.

4.Use the SPACE bar to toggle to the appropriate setting (Enabled or Disabled).

5.If setting more than one network, repeat steps 3 and 4 for each one and then proceed to step 6.

6.Use the arrow keys to highlight the SAVE command.

7.Press ENTER. The message “SAVED OK” displays and all settings are saved.

5.19.3 Setting All Ports

All the network ports on a connector can be set to the same operating mode simultaneously using the SET ALL PORTS field, as follows:

1.Use the arrow keys to highlight the CONNECTOR # field.

2.Use the SPACE bar to step to the appropriate connector number.

3.Use the arrow keys to highlight the SET ALL PORTS field.

4.Use the SPACE bar to step to the appropriate Operating Mode (Auto-Neg, 10Base-T, or 100Base-TX).

5.Use the arrow keys to highlight the SAVE command.

6.Press ENTER. The message “SAVED OK” displays and all networks of the connector are set to the selected operating mode.

5-70

2H23-50R/2H33-37R User’s Guide