5.7.8Setting the Screen Lockout Time

Chapter 5: Local Management

5.7.8Setting the Screen Lockout Time

The screen lockout time can be set from 1 to 30 minutes with a default of

15 minutes. To set a new lockout time, perform the following steps:

1.Use the arrow keys to highlight the Screen Lockout Time field.

2.Enter a number from 1 to 30.

3.Press ENTER to set the lockout time in the input field.

4.Use the arrow keys to highlight the SAVE command at the bottom of the screen and press ENTER.

If the time entered is within the 1 to 30 minutes range, the message “SAVED OK” displays at the top of the screen. If the entry is not valid, Local Management does not alter the current setting, but it does refresh the Screen Lockout Time field with the previous value.

5.7.9Setting the Operational Mode

To set the Operational Mode, proceed as follows:

1.Use the arrow keys to highlight the Operational Mode field.

2.Press the SPACE bar to step to the appropriate operation mode,

(802.1D SWITCHING, 802.1Q SWITCHING, or SECURE FAST VLAN).

3.Use the arrow keys to highlight the SAVE command, then press ENTER. The warning screen shown in Figure 5-12displays.