Cabletron Systems Using LANVIEW, 2H23-50R/2H33-37R User’s Guide, 1 LANVIEW LEDs, Color, State

Models: 2H23-50R 2H33-37R

1 182
Download 182 pages 26.68 Kb
Page 45
Image 45

 

 

 

Using LANVIEW

 

 

Table 4-1 LANVIEW LEDs

 

 

 

 

LED

Color

State

Recommended Action

 

 

 

 

 

 

 

 

PWR

Green

Functional. Power

No action.

 

 

supplies operating

 

 

 

normally.

 

 

 

 

 

 

Amber

Indicates loss of power

1.Ensure that the power cords

 

 

supply redundancy.

are plugged in correctly and

 

 

 

that there is power at the

 

 

 

power source.

 

 

 

2.If the LED remains amber,

 

 

 

contact the Cabletron

 

 

 

Systems Global Call Center.

 

 

 

 

CPU

Off

Power off.

Power up device.

 

 

 

 

 

Red

Blinking. Hardware

Contact the Cabletron

 

 

failure has occurred.

Systems Global Call Center.

 

 

 

 

 

 

Solid. Resetting,

No action.

 

 

normal power up reset.

 

 

 

 

 

 

Amber

Blinking. Crippled.

Contact the Cabletron

 

 

 

Systems Global Call Center.

 

 

 

 

 

 

Solid. Testing.

No action.

 

 

 

 

 

Green

Solid. Functional.

No action.

 

 

 

 

 

Amber

Booting. Blinks amber

No action.

 

and

and green while

 

 

Green

booting.

 

 

 

 

 

Interface

Off

No link. No activity.

No error.

RX

 

Port enabled or

 

(Receive)

 

disabled.

 

of

 

 

 

Green

Solid. Port enabled,

No error.

CONN 1–

 

link, no activity.

 

CONN 4

 

 

 

 

 

 

Blinking. Port

No error.

and Ports 5

 

 

disabled, link.

 

and 6

 

 

 

 

 

or

Amber

Flashing. Port

No error.

CONN 1–

 

enabled, link, activity.

 

CONN 3

 

 

 

Red

Diagnostic failure.

Contact the Cabletron

(2H23-50R)

 

 

Systems Global Call Center

 

 

 

 

 

 

for help.

 

 

 

 

2H23-50R/2H33-37R User’s Guide

4-3

Page 45
Image 45
Cabletron Systems manual Using LANVIEW, 2H23-50R/2H33-37R User’s Guide, 1 LANVIEW LEDs, Color, State, Recommended Action