Chapter 5: Local Management

If the time entered is within the 1 to 30 minutes range, the Event Message Line at the top of the screen displays “SAVED OK”. If the entry is not valid, Local Management does not alter the current setting, but it does refresh the Screen Lockout Time field with the previous value.

5.15.9 Setting the Operational Mode

To set the Operational Mode, proceed as follows:

1.Use arrow keys to highlight the Operational Mode field.

2.Press the SPACE bar to step to the appropriate operation mode, (802.1D SWITCHING, 802.1Q SWITCHING).

3.Use the arrow keys to highlight the SAVE command, then press ENTER. The warning screen shown in Figure 5-18 displays.

4.Use the arrow keys to highlight the YES command and press ENTER. The changes are saved and the module reboots.

Upon saving the new operational mode, the module will reboot.

If the DLE2X-MA and DLE3X-MA have been set to 802.1Q SWITCHING, refer to your Port Based VLAN User’s Guide to configure the devices for this type of operation.

5.15.10 Setting the Management Mode

To set the management mode, perform the following steps:

Upon saving the new Management Mode, the module will reboot.

If the module will be set to STANDALONE, ensure the following procedures have been completed:

The module has been assigned a unique IP address.

The module has been assigned SNMP community names from the module SNMP Community Names screen (Section 5.16). In STAND ALONE management mode, the module does not use the community names of the DLM6C-AA chassis.

1.Use the arrow keys to highlight the Management Mode field:

5-46 DLE22-MA,DLE32-MA,DLE23-MA and DLE33-MA User’s Guide