Ethernet Full Duplex Configuration Screen

The following section explains each field of the Ethernet Full Duplex Configuration screen.

PORT # (Read-only)

Identifies the number of the port.

OPERATION MODE (Toggle)

Allows the user to set the specified port to transmit and receive data separately or simultaneously. Set this field to one of the following values:

STANDARD ENET – The port is running at 10 Mbps (default) and either transmits data or receives data, but not both at the same time. To set Ethernet ports for Full Duplex operation, refer to Section 5.19.1.

FULL DUPLEX – The port transmits and receives data at the same time (full duplex) and operates at 20 Mbps. To set Ethernet ports for Full Duplex operation, refer to Section 5.19.1.

LINK STATUS (Read-only)

Indicates whether there is a physical connection from this port to another Ethernet device. One of the following values displays:

Link – There is a valid link signal present; there is a valid physical connection from this port to another device.

No Link – There is no valid link signal present; there is no valid physical connection from this port to another device.

PORT STATUS (Read-only)

Indicates whether the port was turned on or off administratively. One of the following values is displayed:

ENABLED – The port is turned on administratively.

DISABLED – The port is turned off administratively.

Enabling or disabling ports from the Switch Configuration screen is described in Section 5.18.3.

DLE22-MA,DLE32-MA,DLE23-MA and DLE33-MA User’s Guide 5-61

Page 125
Image 125
Cabletron Systems DLE22-MA, DLE33-MA, DLE32-MA, DLE23-MA manual Ethernet Full Duplex Configuration Screen