Appendix C: Mode Switch Bank Settings and Optional Installations

Figure C-1 shows the location of the mode switches and the switch settings for normal operation.

Flash

DRAM

MODE SWITCH BANK

OFF ON

1

2

3

4

5

6

7

8

LKG-10976-98F

Figure C-1 DLE2X-MA and DLE3X-MA Mode Switch

Location/Component Layout

Switch definitions and positions are as follows:

Switches 1 through 4 – For Digital Equipment Corporation use only.

Switch 5 – COM Port Autobaud. The d efault (OFF) position enables Autobaud sensing on the COM port for Local Management sessions. Changing the switch to the ON position disables Autobaud sensing and sets the COM port to 9600 baud for Local Management sessions.

Switch 6 – Forced BootP. Changing the position of this switch (i.e., moving the switch from one position to the other) clears download information from NVRAM and forces the DLE2X-MA and DLE3X-MA to download a new image file from a BootP server after power to the chassis is restored, or the RESET button is pressed.

C-2 DLE22-MA, DLE32-MA, DLE23-MA and DLE33-MA User’s Guide