Cabletron Systems DLE32-MA, DLE33-MA, DLE22-MA, DLE23-MA manual Troubleshooting Checklist

Models: DLE32-MA DLE33-MA DLE23-MA DLE22-MA

1 202
Download 202 pages 7.28 Kb
Page 62
Image 62

Chapter 4: Troubleshooting

4.3TROUBLESHOOTING CHECKLIST

If the DLE2X-MA or DLE3X-MA is not working properly, refer to Table 4-4 for a checklist of possible problems, causes, and recommended actions to resolve the problem.

Table 4-4 Troubleshooting Checklist

Problem

Possible Cause

Recommended Action

 

 

 

 

 

 

 

Loss of power to the

Check the proper connection

 

of the power cable and its

 

DLM6C-AA chassis.

 

access to a live outlet.

All LEDs are OFF.

 

 

 

DLE3X-MA or

 

 

 

 

DLE2X-MA not properly

Check the installation.

 

installed.

 

 

 

 

 

Autobaud enabled. But

Press ENTER (RETURN)

 

baud rate has not yet

 

(may take up to four times).

No Local

been sensed.

 

 

 

Management

Terminal setup is not

Refer to Chapter 5 for proper

Password screen.

correct.

setup procedures.

 

 

 

 

Improper console cable

Refer to Appendix A for

 

pinouts.

proper console port pinouts.

 

 

 

 

Improper Community

Refer to Chapter 5

 

for Community Names Table

 

Names Table.

Cannot contact the

setup.

 

DLE32-MA or

 

 

DLE2X-MA or

Refer to Chapter 5 for IP

DLE22-MA from

DLE3X-MA does not

address assignment

in-band

have an IP address.

procedure.

management.

 

 

Port is disabled.

Enable port.

 

 

 

 

 

No link to device.

Check link to device.

 

 

 

Port(s) goes into

DLE2X-MA or

Review network design and

standby for no

DLE3X-MA detects a

delete unnecessary loops.

apparent reason.

looped condition.

 

 

 

 

User parameters (IP

Mode switch (7),

 

address, Device and

NVRAM Reset, was

 

Module name, etc.)

changed sometime

 

are lost when the

before either cycling

Reenter the lost parameters

DLE2X-MA or

power or pressing the

as necessary. Call your

DLE3X-MA is

RESET button, causing

DIGITAL representative if

powered down or

the user-entered

problem continues.

the front panel

parameters to reset to

 

RESET button is

factory default settings.

 

pressed.

 

 

 

 

 

4-6 DLE22-MA, DLE32-MA, DLE23-MA and DLE33-MA User’s Guide