Installing Optional Fast Ethernet Interface Modules

To install a Fast Ethernet Interface Module in port slot 25 or 26 of the DLE2X-MA, proceed as follows:

The Fast Ethernet Interface Module and the host module are

!sensitive to static discharges. Use an antistatic wrist strap and observe all static precautions during this procedure. Failure to do so could damage the Fast Ethernet Interface Module or the host module.

The DELF3-UI uses Class 1 lasers. Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases eye hazard. When viewing the output optical port, power must be removed from the network adapter.

1.Remove the coverplate from the port slot where the Fast Ethernet Interface Module will be installed.

When installing Fast Ethernet Interface Modules in both port slots 25 and 26, remove the coverplates from both slot openings. In the following instructions, the optional module is shown being installed in port slot 26.

To remove a coverplate, refer to Figure C-3 and proceed as follows:

a.Remove the two screws fastening the coverplate to the standoffs. Save the screws.

b.Lift and remove the coverplate from the top of the front standoffs.

DLE22-MA, DLE32-MA, DLE23-MA and DLE33-MA User’s Guide C-5

Page 193
Image 193
Cabletron Systems DLE22-MA, DLE33-MA, DLE32-MA, DLE23-MA manual Installing Optional Fast Ethernet Interface Modules