Setting the Mode Switch
DLE22-MA, DLE32-MA, DLE23-MA and DLE33-MA User’s Guide C-3
Switch 6 – After changing the position of switch 6 and restarting the
module, the DLE2X-MA and DLE3X-MA request a new image
download until they either receive a new image or the RESET button
on the front panel is pressed. When the RESET button is pressed, the
DLE2X-MA and DLE3X-MA continue trying to contact a BootP
server, but will time out in approximately one minute. If the module
times out, the image is downloaded from its FLASH memory.
Switch 7 – Clear NVRAM. Changing the position of this switch resets
NVRAM on either the next power up or the next operation of the front
panel RESET switch. ALL user-entered parameters, such as IP
addresses, subnet masks, SNMP traps, and bridging functions are
restored to their factory default settings.
Switch 8 – Reset Password/Community Strings. Changing the position
of this switch clears only the user-entered passwords stored in
NVRAM, and restores the default passwords. Once the DLE2X-MA
and DLE3X-MA are reset, the passwords can either be reentered or the
default passwords (Public and ENTER) may be used.
After changing the position of switch 6, DO NOT reapply power
to the chassis or reset the module until there is a station acting
as a BootP server, which contains the image file.
Do not change the position of switch 8 unless it is necessary to
reset the module super-user configured passwords to their
factory default settings.