Chapter 5: Local Management

5.17BROADCAST SUPPRESSION SCREEN

NOTE

The Broadcast Suppression screen will display only if the operational mode of the device has been set to 802.1D SWITCHING or 802.1Q SWITCHING. Refer to Section 5.7.9, Setting the Operational Mode for instructions on configuring the device to operate in this mode.

The Broadcast Suppression screen, Figure 5-22, allows the user to set a desired limit of receive broadcast frames that are switched out to the other interfaces. This feature limits the amount of broadcast packets to the threshold setting (1 second) and drops all other broadcast packets until the 1 second threshold elapses. This screen also provides statistics about the broadcast activity on ports 1 through 4.

To access the Broadcast Suppression screen from the Device Specific Configuration Menu screen, use the arrow keys to highlight the BROADCAST SUPPRESSION menu item and press ENTER. The Broadcast Suppression screen displays.

Event Message Line

 

 

2M46-04R LOCAL MANAGEMENT

 

 

 

 

 

Broadcast Suppression

 

 

 

Device Type: 2M46-04R

 

 

Firmware Revision: XX.XX.XX

 

 

 

 

BOOTPROM Revision: XX.XX.XX

Port #

Total RX

Peak Rate

Time Since Peak

Threshold

Reset Peak

1

12345678910

150000

999:23:59

150000

[NO]

2

12345678910

150000

999:23:59

150000

[NO]

3

12345678910

150000

999:23:59

150000

[NO]

4

12345678910

150000

999:23:59

150000

[NO]

 

 

 

 

 

 

RETURN

 

SAVE

 

EXIT

 

 

RETURN

2314-56

Figure 5-22 Broadcast Suppression Screen

5-56

2M46-04R/2M46-04RDC User’s Guide

Page 104
Image 104
Cabletron Systems pmn manual Broadcast Suppression Screen