Completing the Installation

4.Verify that a link exists by checking that the port RX LED is ON (flashing amber, blinking green, or solid green). If the RX LED is OFF and the TX LED is not blinking amber, perform the following steps until it is on:

a.Check that the power is turned on for the device at the other end of the fiber optic cable.

b.Verify proper crossover of fiber strands between the applicable port on the 2M46-04R and the fiber optic device at the other end of the fiber optic cable.

c.Verify that the fiber connection meets the dB loss specifications outlined in the Cabletron Systems Cabling Guide.

If a link is not established, see Chapter 4, Troubleshooting, before contacting the Cabletron Systems Global Call Center (refer to Section 1.5, for details).

3.6COMPLETING THE INSTALLATION

After installing the 2M46-04R and any optional Fast Ethernet Interface Modules and HSIMs as appropriate, and making the connections to the network, proceed as follows:

1.Secure the cables by running the cables along the strain-relief bracket and tying them to the strain-relief bracket using cable ties.

2.The 2M46-04R is now ready to be set up through Local Management. Refer to Chapter 5, Local Management, for information on how to access and use Local Management to configure the 2M46-04R.