Cabletron Systems pmn Port Type Read-only, Link Status Read-only, Current Oper. Mode Read-only

Models: pmn

1 150
Download 150 pages 2.96 Kb
Page 93
Image 93
Port Type (Read-only)

High Speed Interface Configuration Screen

The following briefly explains each field of the High Speed Interface Configuration screen:

Port Type (Read-only)

Displays the type of interface (FE-100FX, FE-100TX, FE-100F3, or Unknown) installed in ports 1 and 2. Figure 5-19shows that there is an FE-100TX interface installed in port 1 and no interface, indicated by Unknown, in port 2.

Link Status (Read-only)

Indicates whether or not there is a physical connection from this port to another 10BASE-T or 100BASE-TX/FX device. One of the following values displays:

Link – There is a link signal present and a valid physical connection to another device.

No Link – There is no link signal present and no valid physical connection to another device.

Current Oper. Mode (Read-only)

This field displays the current operating mode of ports 1 and 2. Depending on whether a 100BASE-FX, or 100BASE-TX is installed, this field displays the following:

With a 100BASE-FX interface: 100Base-FX, 100Base-FXFD (full duplex), or N/A when port is empty.

With a 100BASE-TX interface: Unknown, 10Base-T, 10Base-TFD (full duplex), 100Base-TX, 100Base-TXFD(full duplex) or N/A when port is empty.

Desired Oper. Mode (Selectable)

This field allows the user to select the desired operational mode for an interface in port 1 or 2. The field toggles between 100Base-FX and 100Base-FXFD (full duplex) when an FE-100FX or FE-100F3 is installed. Section 5.14.1 describes how to configure a port with an FE-100FX or FE-100F3.

2M46-04R/2M46-04RDC User’s Guide

5-45

Page 93
Image 93
Cabletron Systems pmn manual Port Type Read-only, Link Status Read-only, Current Oper. Mode Read-only