Proceed as follows to install the 2M46-04R into a 19-inch rack.

Installing the 2M46-04R

Screws (4)

Strain-Relief Bracket

2

1

RESET 04R-2M46

 

 

COM

 

 

CPU

 

 

PWR

 

1 HSIM

2 HSIM

2314-47

Figure 3-2 Attaching the Strain-Relief Bracket

There are two methods for attaching the rackmount brackets for the 2M46-04R and 2M46-04RDC. Proceed to the section entitled Rackmounting the 2M46-04Rfor instructions on installing the

2M46-04R, or the section entitled Bonding the Rackmount Brackets to the 2M46-04RDC, which discusses the GR-1089-CORE Section 9 bonding requirements for the 2M46-04RDC when installing rackmount brackets.

Rackmounting the 2M46-04R

Proceed as follows to install the 2M46-04R into a 19-inch rack.

1.Remove and discard the four cover screws (two from each side) located along the front edges of each side of the 2M46-04R.

2.Locate the four 6-32 x 3/8-inch flat head cover replacement screws in the rackmount kit. Use these screws to attach the rackmount brackets

to the 2M46-04R as shown in Figure 3-3.

2M46-04R/2M46-04RDC User’s Guide

3-5