![](/images/new-backgrounds/1110468/110468539x1.webp)
CLI Commands
set
set (v35)
Use the set (v35) command to setup V.35 ports. The command specifies the range of channels within that card, and the setting to apply.
Syntax: set
Example: set 6:1 rxclk normal
To set port 1 (v.35) on slot 6 to no inversion on the receive clock
{v35-addr}
In the form of {slot:port}.
slot | Slot number |
port | Port number or range. |
|
|
{setting}
Setting to apply one of the following:
| clock | Set the clock source to one of the following: | |
|
| external | to the external source |
|
|
|
|
|
| source | to the internal Stratum 4E oscillator |
|
|
|
|
| cts | Set the Clear | To Send operation mode to one of the following: |
|
|
|
|
|
| cd | follow CD |
|
|
|
|
|
| high | force CTS high |
|
|
|
|
|
| low | force CTS low |
|
|
|
|
|
| rts | follow RTS |
|
|
|
|
| data | Set the data | mode to one of the following: |
|
|
|
|
|
| invert | invert the receive and transmit data |
|
|
|
|
|
| normal | do not invert receive and transmit data |
|
|
|
|
| equipment | Sets the V.35 | port to equipment loopback, which loops the transmit V.35 |
|
| signal back toward the V.35 receive (toward the T1) | |
|
|
|
|
|
| loopdown | disable equipment loopback |
|
|
|
|
|
| loopup | enable equipment loopback |
|
|
|
|
| line | Sets the V.35 | port to line loopback, which loops the received V.35 signal |
|
| back toward the V.35 signal toward the V.35 transmit (away from T1) | |
|
|
|
|
|
| loopdown | disable line loopback |
|
|
|
|
|
| loopup | enable line loopback |
|
|
|
|
| rxclkinv | Set the receive | clock invert mode to one of the following: |
|
|
|
|
|
| invert | invert the receive clock |
|
|
|
|
|
| normal | do not invert the receive clock |
|
|
|
|
Axxius 800 - Release 2.2 |