Configuration

Basic System Setup

Setup of ADPCM

Command

Description

Connect T1 cable to port 1 of the ADPCM service card

set {adpcm_card-addr}

Enable compressing by selecting Map type. Note:

{nonemap1map2map3}

none disables compression.

 

 

show (adpcm_card-addr}

Displays the status of the card, and the mapping.

 

 

connect 2:1:1-12 2:4:1-12

Set ADPCM cross-connects. The example

 

connects all 24 channels of the ADPCM to the 12

 

channels of the T1 (now compressed) on port 4.

 

This example is with map2

 

 

show connect {2:1)

Displays the connections made above.

 

 

Set Up a V.35 Port

Use the following commands to set up a V.35 port.

Command

Description

 

 

set {v35-addr} cts

Set the Clear to Send operation mode. See set

{cdhighlowrts}

(v35) command for details.

 

 

set {v35-addr} data

Set the data mode. See set (v35) command for

{invertnormal}

details.

 

 

set {v35-addr} clock

Set the clock mode. See set (v35) command for

{sourceexternal}

details.

 

 

set {v35-addr} speed

Set the speed. See set (v35) command for details.

{56K64K}

 

 

 

set {v35-addr} txclkinv

Set the transmit clock inversion mode. See set

{invertnormal}

(v35) command for details.

 

 

set {v35-addr} rxclkinv

Set the receive clock inversion mode. See set

{invertnormal}

(v35) command for details.

 

 

 

 

 

 

Axxius 800 - Release 2.2