OCU-DP Card

Features

Features

λProvides available baseband data rates from 2.4 to 72 Kbps

λSupports primary and secondary channel services, 64K clear channel service, and 4-wire Switched-56 service

λComplies with AT&T Pub. 62310

λOffers Bipolar Violation (BPV), Loss of Frame (LOF-DDSII), Loss of Signal (LOS) and Out-of-Service (OOS) performance counters: 15 minute, 1 hour and 24 hour intervals available

λOffers BPV, OOS, LOF and LOS selectable alarm thresholds

λSupplies built-in self-tests including data path and RAM test status and TDM and CSU failures

λSupports DDS network control codes for OCU, CSU and DSU latching and non- latching service loopbacks

λSupports system timing from any T1 line and provides it to the connected DTE

λDeploys up to 32 OCU-DP service ports in a single Axxius 800 chassis

Technical Specifications

Controller Software and Hardware Required

λRelease 1.1 or higher is required for the OCU-DP service card

λ-48V NI48V Power Supply (P/N 740-0084) is required for this card

Service Interface

λSingle-port OCU-DP interface

-

-

One RJ-48S front-panel jack Wire-wrap pins for rear-panel connection

λQuad-port OCU-DP interface

-

-

Four RJ-48S front-panel jack Wire-wrap pins for rear-panel connection

 

 

 

 