![](/images/new-backgrounds/1110468/110468349x1.webp)
CLI Commands
set
set clock (1 and 2)
Use the set clock (1 and 2) command to set the master transmit clock. The primary master clock source may be used to clock each DS1 transmitter. The clock circuit automatically switches to the secondary clock source if the primary clock fails.
Syntax: set {clock1clock2} {source}
Example: set clock1 a:1
To set the primary master clock source to A:1.
Example: set clock2 1:2
Set the secondary master clock source to Quad T1 in slot 1 source selected.
{clock1}
Set primary master transmit clock source.
{clock2}
Set secondary master transmit clock source.
{source}
Set the clock source to one of the following:
| bits1_t1 | Select BITS1 T1 |
| bits2_t1 | Select BITS2 T1 |
|
|
|
| Clock recovered from the BRI port on the BRI card (BRI card must be in | |
|
| LUNT and 3DS0 mode) |
|
|
|
| Clock recovered from the DS1 receiver | |
|
|
|
| internal | Internal stratum 4E oscillator |
|
|
|
NOTE: To set DS3 clocking see set (ds3) clock command.
set date
Use the set date command to set the date.
Syntax: set date {mm/dd/yyyy}
Example: set date 1/1/2002
The example will set the date to January 1, 2002.
{mm/dd/yyyy}
mmRepresents the month. Range is
ddRepresents the Day. Range is
yyyyRepresents the year. Range is
|
|
|
|
Axxius 800 - Release 2.2 |