Installing the System Fan

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the system and protecting against electrostatic discharge.

1Hold the replacement fan with the fan cable on the left side (opposite of the power supply), and align the edges of the fan with the securing slots.

2Slide the fan left into the securing slots until the fan release tab locks into place. See Figure 3-32.

3Connect the cable to the FAN_2 connector on the system board (see Figure 6-1 for the connector location).

4Install the processor shroud. See "Installing the Processor Shroud" on page 74.

5Install the expansion card shroud. See "Installing the Expansion Card Shroud" on page 75.

6Close the system. See "Closing the System" on page 70.

7Place the system upright and on its feet on a flat, stable surface.

8Reattach any peripherals, then connect the system to the electrical outlet.

9Turn on the system and attached peripherals.