Table 1-5. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E141F

CPU Protocol

The system BIOS has

See "Getting Help" on

 

 

reported a processor

page 205.

 

 

protocol error.

 

E1421

CPU Init

The system BIOS has

See "Getting Help" on

 

 

reported a processor

page 205.

 

 

initialization error.

 

E1422

CPU Machine

The system BIOS has

See "Getting Help" on

 

Chk

reported a machine check

page 205.

 

 

error.

 

E1610

PS # Missing

No power is available from

See "Troubleshooting

 

 

the specified power supply;

Redundant Power

 

 

specified power supply is

Supplies" on page 171.

 

 

improperly installed or

 

 

 

faulty.

 

E1614

PS # Status

No power is available from

See "Troubleshooting

 

 

the specified power supply;

Redundant Power

 

 

specified power supply is

Supplies" on page 171.

 

 

improperly installed or

 

 

 

faulty.

 

E1618

PS #

Power supply voltage is out

See "Troubleshooting

 

Predictive

of acceptable range;

Redundant Power

 

 

specified power supply is

Supplies" on page 171.

 

 

improperly installed or

 

 

 

faulty.

 

E161C

PS # Input

Power source for specified

Check the AC power

 

Lost

power supply is unavailable,

source for the specified

 

 

or out of acceptable range.

power supply. If the

 

 

 

problem persists, see

 

 

 

"Troubleshooting

Redundant Power

Supplies" on page 171.

24

About Your System

Page 24
Image 24
Dell DR715 E141F CPU Protocol, E1421 CPU Init, E1422 CPU Machine, Chk, E1610 PS # Missing, E1614 PS # Status, E1618 PS #