Table 1-6. System Messages

Message

Causes

Corrective Actions

 

 

 

Alert! Redundant

Redundant memory was set

See "General Memory

memory disabled!

to enable in CMOS, but the

Module Installation

Memory

current configuration does

Guidelines" on page 127 for

configuration

not support redundant

memory configuration

does not support

memory.

information. If the problem

redundant

 

persists, see

memory.

 

"Troubleshooting System

 

 

Memory" on page 174.

Alert!

A spare rank event occurred

Redundancy was

during the previous boot.

previously lost.

 

Power cycle

 

required to

 

reconfigure

 

redundant

 

memory.

 

Attempting to

Remote Configuration

update Remote

request has been detected

Configuration.

and is being processed.

Please wait...

 

See "General Memory

Module Installation Guidelines" on page 127 for memory configuration information. If the problem persists, see "Troubleshooting System Memory" on page 174.

Wait until the process is complete.

BIOS Update

Remote BIOS update

Retry the BIOS update. If

Attempt Failed!

attempt failed.

problem persists, see

 

 

"Getting Help" on page 205.

Caution!

NVRAM_CLR jumper is installed on system board.

NVRAM_CLR jumper is installed. CMOS has been cleared.

Remove NVRAM_CLR jumper (see Figure 6-1 for jumper location).

Decreasing

Faulty or improperly installed

See "Troubleshooting System

available memory

memory modules.

Memory" on page 174.